Item Description YMGI 30000
BTU DUAL ZONE 12000 BTU + 18000 BTU DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP 208-230V 22 SEER DC INVERTER MITSUBISHI COMPRESSOR Model : WMMS-30CH-V2B(59)4/12EW-18EW Condition : Brand New item unused unopened in original
sealed package Function Cooling Heating Dehumidification Air
Purification Description Dual
Zone Air Conditioner with Heat Pump One
Outdoor unit with 2 Indoor units (12000 BTU, 18000 BTU) 30000
BTU Heating Cooling And Dehumidification 22 SEER DC Inverter Compressor from Mitsubishi Super
Quite Auto Restart, digital Timer and Turbo Mode Condenser Max output : 30000 BTU Cooling 32000 BTU Heating Feature Variable
Speed Compressor: Mitsubishi 22 SEER efficiency, DC inverter technology AHRI
certified Whisper-quiet
operation, Low voltage start Stable
Operation at Low Frequency Random
pitch cross flow fan wheel Dry
anti-mould coil LCD
display, Turbo mode, 3 fan speeds Quick
access, washable air filter Auto
level swing, Wide angle air distribution, Auto Restart, 24-hour
programmable timer, Sleep mode, Independent Dehumidification Enhanced
copper/coil, Corrosion resistant cabinet, Thoroughly tested ensure longer
performance YMGI Smart Technologies · Auto-Restart : After a power cut the unit will
restart automatically with the previous function setting when the power
returns. · Intelligent
Auto-Defrosting: The
unit can enter or quit the defrosting mode automatically by timely
detecting the frosting situation of the outdoor unit. · Sleep
Mode: Because
our body temperature cools down as we sleep, the unit automatically adjusts the
setting for all-night comfort. · Air
Purifying and Deodorizing Filters: Industrial
development has offered from one side a better life style, but on the other
side, it has increased polluting substances presence in the air that helps in
spreading of various kinds of diseases. Among the polluting agents, the ones we
can more frequently find at home are anti-bacterial dust particles, moulds and
etc, which are causing allergic phenomenon, breathing and typical upper
respiratory problems. This dual washable filter screen is effective in
preventing anti-bacteria mould and duct particles and ensuring a healthy indoor
environment. · Turbo
Mode: This
function enables the unit to reach the preset temperature in the shortest time. · Self-diagnosis
and Auto-Protection Function: This
function can electronically detect the errors and display the diagnosis by a
series of flashing LEDs on the indoor unit. Then the unit will automatically
switch to protection mode. IMPORTANT NOTES ABOUT
THE DC INVERTER SYSTEM VARIOUS PERFORMANCES · The
rated performance data printed on the nameplate were tested per AHRI 210/240
standards at standard indoor & outdoor conditions and standard installation
set-up. · Actually
the DC inverter outdoor unit could modulate to match whatever capacity needs
are called/requested from indoor side, to produce a wide range of capacities,
minimum could be about 15% of the rated number and maximum could be around 160%
of the rated number. · Once
the DC inverter system is installed, each indoor unit's output and so the
outdoor unit performance will all vary over the operation period: soft
starting, turbo quick cooling/heating, maintaining, defrosting, switching, and
other condition changes. · Actual
performance varies upon many factors such as indoor and outdoor temperatures,
inter-connecting pipe length/ bending, elevation difference between indoor and
outdoor units, refrigerant charging level, vacuum level, leakage, air or
moisture or contamination level, foreign substance left in the piping, indoor
filter clean level, indoor and outdoor coil conditions, and other factors. · When
the rated total capacity of all the indoor units exceeds the rated capacity of
outdoor unit, each indoor unit may not output the rated capacity and one may
differ from other, upon other installation/operation factors, it all units are
turned on to run compressor simultaneously. PIPE ADAPTER · Whenever
the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas
pipe of 1/2" or 5/8", one 3/8" - 1/2" or 3/8" -
5/8" adapter is to be used in between. This reducer is packed
separately and shall be installed at job site. · Any
indoor unit is 30' or more apart from the outdoor unit, better to adjust
refrigerant. If it is 50' or more apart, better to upper size the copper lines
and adjust refrigerant. · Any
run cannot be more than 100' apart from the outdoor unit; otherwise, that
indoor unit capacity may be reduced BTU / Area Coverage Guide
12000 BTU covers Approx 500 ft²
18000 BTU covers Approx 75 0 ft²
24000 BTU covers Approx 1100 ft² * Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those affect insulation. Specification: BTU / Area Coverage Guide 9000 BTU covers Approx
400 ft² 12000 BTU covers
Approx 500 ft² 18000 BTU covers Approx
750 ft² 24000 BTU covers Approx
1100 ft² * Cover area is a guide
only, other factors should also take into consideration such as ceiling height,
number of windows and wall material those affect insulation. Application Bar and Pub Hotel Home Office Green House Condos Resort Factory Nursing Home Residential Apartment Office Restaurant Package Include Condenser
R410A pre-charged (outdoor unit) 2
X Air Handler w/wall bracket ( for indoor unit) 2
X Wireless Remote control Installation
kit (Insulated copper line set with nuts, control
cable and misc.) Installation
and Operation Manuals Manufacturer
warranty Certificate Warranty All YMGI products
come with standard 5 years limited warranty for compressor and 1 year limited
warranty of parts for indoor units and installation kit. If you have any
questions related to the operation of your equipment you are always welcome to
contact us by email or phone and we will there to assist. Our contact information
will be available in the warranty certificate. Notice and Installation YMGI does not provide installation
for equipment. Customer will need to hire a licensed HVAC technician and
install the equipment in a professional manner. Installation by unlicensed personnel
will automatically void YMGI standard warranty and it is strongly not
recommended as it may cause danger to your property. YMGI and bizlander cannot
be held liable for any damage that caused by improper installation. Please be advised that federal law prohibits opening any
refrigeration line by anyone not properly licensed. Please be noted returned warranty
certificate will be deemed as valid only if it is signed, dated and noted with
details of technician which responsible for the installation. Disclaimer YMGI endeavour to
ensure all information given here (include technical data, and other
information) is correct. However due to omissions, errors and out-of-date data
from constant improvement, YMGI and bizlander reserve all rights to modify any
part of the content without notice. Every reasonable effort has been made to
ensure all information contained here is correct.
More Items!
Packaged Terminal Air Conditioner Heat pumpYMGI 12000 BTU 3KW Heater 220V July
$969.00
Packaged Terminal Air Conditioner Heat pumpYMGI 12000 BTU 3KW Heater 220V Jun
$969.00
Packaged Terminal Air Conditioner Heat pumpYMGI 12000 BTU 3KW Heater 220V May
$969.00
Packaged Terminal Air Conditioner Heat pumpYMGI 12000 BTU 3KW Heater 220V Apr
$969.00
Listed by Frooition
Frooition | No-js Template | Pricetronic design, Pricetronic store design, Pricetronic shop design, Pricetronic template design, Pricetronic listing design, Pricetronic Listing Tool (ver:froo_no_js)
Returns Accepted for this item if it's within 30 Days