36000 BTU Ductless Split AC: CEILING-FLOOR
Inverter w/ 36,000 BTU Heat Pump Thermocore T3C18S-H236-ED T3 Series Ductless Mini Split : Suspended Ceiling-Floor Mount. 36000 BTU Inverter Cooling Capacity along with a 36,000 BTU Heat Pump, this 3 TON Ductless Split can cool or heat an area over 1600 ft². Advanced INVERTER DC Technoloy provides both energy efficient operation and low ambient operation down to 5 degrees in both heat and cool mode. Head suspends from ceiling or placed upright on floor. Comes pre-charged with R410A and includes complete install Kit. Technical Data: System Includes: 36,000 BTU INVERTER Cooling Capacity 36,000 BTU INVERTER Heat Pump 17.5 SEER - 10.5 HSPF - AHRI CERTIFIED
Pre-Charged with ECO-Friendly R410A 1 Year Parts - 5 Year Compressor Warranty Indoor Unit - Suspended Ceiling Air Handler. Outdoor Unit - Compressor. Digital Multi-function LCD Remote Control. Installation Kit with 15ft of lineset and wire. Product and Installation Manual. Top Line Features: 17.5 SEER - 10.5 HSPF - 9.0 EER Suspended from ceiling or floor placement Pre-Charged w/ Eco-friendly R410A Refrigerant Ideal for Large Commercial Applications Built in Drain Pump removes Moisture Cross Flow Technology reduces noise output Freon Leak Detection > Notification system Low Ambient Temperature Operation (5° F) Restart IC: Settings restored Following Outage Follow-Me Function tracks Remote Location Model Number T3C18S-H236-ED Capacity 36000 BTU Air Flow (Hi/M/Lo) 1762/1559/1084 (m3/h) Power Supply 230 V / 60 Hz / 1Ph Noise Output (Hi/M/Lo) 54/49/43 dBA Liquid / Gas 3/8" x 5/8" Weight 69 lbs Body Dimensions (W x D x H) 50.6" x 26.6" x 9.25" inches Model Number
T3C18S-H236-C Compressor
Toshiba (GMCC) Capacity 36000 BTU Heating Capacity 38000 BTU Air Flow
4300 m3/h Power Supply
208-230 V / 60 Hz, 1Ph Input Power
9490W Min Input Current
30A SEER
17.5 EER 9.0 HSPF
10.5 Maximum Fuse
50A Sound Level
66 dB Refrigerant
R410A / 25ft (Pre-Charged) Maximum Pipe Length 213 ft Maximum Elevation 98 ft Operating Temperature
5 - 122 F Weight
220.5 Lbs Dimensions (W x D x H)
37.24 x 16.14 x 31.9inches Install Kit Contents: 15 Feet Flared Copper Tubing 15 Feet Pipe Insulation 15 Feet Electrical Wire Harness Drain Pipe (Indoor) Hanging Bracket Kit for Indoor Unit Binding Belt - Catchment Trough Remote Control and Install manuals Extend included 15 foot copper lineset to 25-30-40-50-60-75 feet. Just $8.00 / ft WHAT IS DC INVERTER? DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically. Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained. BASIC OVERVIEW: The installation of a suspended ceiling mount is much like that of a ductless mini split with the exception that instead of a wall mounted air handler, a suspended ceiling unit mounts hanging from a ceiling or positioned on a flat surface. The indoor unit (ceiling cassette) and outdoor unit (condenser) are connected to each other by means of refrigerant copper tubing and electrical cables that are routed through the ceiling and outside to the condenser outputs via a 2-3 inch hole. The compressor comes pre-charged with freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a ceiling cassette system. *Although the installation may seem easy to some, certain tools and experience is necessary to complete installation of a ceiling cassette system. A certified HVAC technician must conduct / complete the installation to be eligible for product warranty.
*5 Year Compressor - 1 Year on all other Parts*
Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS! Our Thermocore systems ship via or similar LTL freight service out of Warren, Michigan and are palletized onto a single skid. Transit time is usually between 4 to 6 business days from payment receipt depending on where you are geographically located. Please provide a contact phone# upon checkout (to be used for delivery purposes only). SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Failure to provide valid contact# will delay order. System comes with Free shipping - this includes delivery to any location within the Continental United States. We will ship to Canadian locations but we need to quote separately - please contact our offices. Additional freight for Canadian registries is usually around $150. (import and duties may apply). Condenser Ground Stand - Provides Flat even surface - Avoids debris obstruction Price: $73.00 Lineset Extension (3/8 x 5/8) - Extend included 16 ft copper lineset to 25ft - 30ft - 40ft - 50ft Price: $38.00 > $134.00 Condenser Bracket - Mount your condenser at any height on an outdoor sidewall Price: $78.00 Micro-Pump II - Required when mounting air handler on Interior wall Price: $182.00 Swap Susp. Ceiling for Cassette: (-) $100 CLICK HERE TO PURCHASE CASSETTE OPTION >>> Swap Susp. Ceiling for Wall Mount: (-) $200 CLICK HERE TO PURCHASE CASSETTE OPTION >>> *If alternate air handler types are preferred, contact us and request invoice with preferred options. Availability fluctuates.
Returns Accepted for this item if it's within 30 Days